Troubleshooting¶
Find your problem below. If it is not listed, contact support.
My computer does not see the device¶
- Check that you use a USB cable that supports data transfer, not only charging.
- Try another USB port, and re-plug the device.
- Make sure the USB-to-serial driver is installed. ZigStar sticks use a CH340 chip; on Windows the driver is normally picked up automatically, otherwise download it from the manufacturer.
- Check that the device shows up: see Determine the USB port for Linux, macOS and Windows.
The web installer says "No device found" or does not offer my port¶
- Use Chrome on a desktop computer.
- Install the driver for the chip on your board. The Web Installer page links the drivers for common ESP boards.
- Make sure your USB cable supports data transfer.
Flashing fails or the device does not enter BSL mode¶
- Follow the exact sequence: unplug the stick, press and hold the BSL button, plug it in, wait a few seconds, then release. See Put your device in BSL mode.
- Boards with the CH340E chip do not support Auto-BSL, so you must press the button manually.
- For network gateways, open the gateway in your browser and use Firmware Update to start bootloader mode.
- Select the correct serial port and the correct target device (for example CC2652P).
Wrong firmware
Using the wrong firmware disables the bootloader (BSL) and you will need an external debugger/programmer to flash the device again. Always check Quick Start, step 2 before flashing.
I need to reset the Zigbee radio (NVRAM)¶
If a flash completed but the coordinator behaves strangely, or you want a fresh start, erase the NVRAM. See Clearing NVRAM, or use the NVRAM tools in the ZigStar Multi Tool.
The LAN gateway cannot be reached¶
- Check the Ethernet cable and that the gateway is powered.
- Try
zigstargw.localin your browser. If your network does not support.local(mDNS) addresses, use the gateway's IP address. - If you use a static IP, reserve it in your router so it does not change after a reboot.
- The two DIP switches must both be in the same position: ON for USB mode, OFF for LAN mode (LAN Gateway).
- LilyZig: never use USB and PoE at the same time, and disconnect the Ethernet cable when you program the board over USB-C.
ESPHome gateway no longer connects after changing the IP settings¶
An error in the IP configuration can stop the gateway from connecting. After changing IP parameters, OTA updates will not work until the firmware is flashed to the ESP module manually. See the ESPHome guide. If the gateway no longer responds at all, re-flash it with a USB-to-serial converter.
Zigbee2MQTT or ZHA cannot connect to the coordinator¶
- Check the connection settings in Connect to Zigbee2MQTT / ZHA: the serial port for sticks, or
tcp://ip_or_hostname:6638(Zigbee2MQTT) /socket://ip_or_hostname:6638(ZHA) for LAN gateways. - In ZHA use port speed 115200 and leave software flow control empty. For TI-based devices select the ZNP radio type.
- In ZHA, if the stick is not detected, re-plug it or try another USB port.
- Zigbee2MQTT shows Network Commissioning Timeout? See the dedicated fix.
Which firmware should I download?¶
See Quick Start, step 2. In short: pick the file that matches your Zigbee module, and choose coordinator or router depending on how you want to use the device.
Zigbee2MQTT or ZHA - which should I use?¶
Both work with ZigStar devices. Zigbee2MQTT supports the TI CC2652P/CC2652RB chips used on these boards; ZHA supports both TI and Silicon Labs chips. See Connect to Zigbee2MQTT / ZHA.